Can you build and pour concrete in cold weather?
Yes. The forms insu­late the con­crete and enhance the cur­ing process. The top of the forms, or exposed con­crete areas will need to be cov­ered, tem­porar­i­ly, with insu­la­tion to pre­vent the exposed con­crete from freez­ing. Fox Blocks projects can be con­struct­ed any time of the year, no delays for cold weath­er.
How are Fox Blocks green/environmentally friendly?
Fox Blocks con­tain a min­i­mum of 40% recy­cled con­tent by weight.
  • Fox Blocks do not off-gas and are not man­u­fac­tured using any gas­es that deplete the ozone or are harm­ful to the envi­ron­ment.
  • Fox Blocks require low embod­ied ener­gy to man­u­fac­ture.
  • Fox Blocks do not con­tain any mate­ri­als, that pro­mote mold or mildew growth.
  • Fox Blocks are an effi­cient con­struc­tion method there­by reduc­ing the amount of con­struc­tion waste, dust and air pol­lu­tion in the build­ing process.
  • Build­ing with Fox Blocks will save on heat­ing and cool­ing costs because less air is exchanged between the out­side and inside of your home. This also means a small­er more effi­cient HVAC unit is required for the home.
  • Fox Blocks are sus­tain­able. They will not rot or dete­ri­o­rate for the life of your home.
  • Fox Blocks pro­vide a secure, durable, com­fort­able, long last­ing build­ing
How much will it cost per square foot to build an Fox Blocks ICF home?

Build­ing with Fox Blocks ICFs pro­vides you with a high per­for­mance wall sys­tem for the foun­da­tion and above grade walls. Build­ing any high per­for­mance home, with either ICFs or con­ven­tion­al wood fram­ing, has many fac­tors that define the end cap­i­tal costs.

What addi­tion­al mate­ri­als and labor are required to make a con­ven­tion­al foun­da­tion equiv­a­lent to an Fox Blocks ICF foun­da­tion which exceeds ener­gy code require­ments in most loca­tions? Con­ven­tion­al wood fram­ing requires con­sid­er­ably more mate­r­i­al, insu­la­tion and atten­tion to air seal­ing to make it qual­i­fy and per­form as a high per­for­mance wall. All of this, for con­ven­tion­al con­struc­tion, adds mate­r­i­al and labor costs to the over­all project. Fox Blocks ICFs pro­vide a sim­ple method to build high per­for­mance walls that pro­vide ongo­ing ben­e­fits from the high insu­la­tion val­ues and mass con­crete walls that are ener­gy-effi­cient and pro­vide cost sav­ings for the life cycle of the build­ing.

Com­par­ing cost per square foot between con­ven­tion­al con­struc­tion and ICFs for a high per­for­mance build­ing, is like com­par­ing apples to oranges. To devel­op con­struc­tion costs, more detailed infor­ma­tion is required, for instance the num­ber and size of open­ings, the shape and size of the home, the region­al costs for mate­r­i­al and labor, etc. If you have a project you’d like us to review and pro­vide a mate­r­i­al esti­mate, Fox Blocks would be hap­py to have one of our rep­re­sen­ta­tives con­tact you. Please com­plete and sub­mit a lead infor­ma­tion sheet on the web­site or call Cus­tomer Ser­vice.

What is the R-Value?

The clear R‑Value of an Fox Blocks is R22, how­ev­er cur­rent Ener­gy codes rec­og­nize the lack of ther­mal bridg­ing in an ICF and the con­tri­bu­tion of the mass con­crete on the influ­ence of the ther­mal per­for­mance. Whole wall cal­cu­la­tions indi­cate a Fox blocks wall assem­bly pro­vides an R24 rat­ing.

The con­tin­u­ous dou­ble lay­er (inside and out­side) of insu­la­tion, the elim­i­na­tion of ther­mal bridg­ing and min­i­mal air infil­tra­tion through the mass con­crete wall assem­bly, allows Fox Blocks walls to per­for­mance in the high per­for­mance wall assem­bly cat­e­go­ry. Com­plet­ing the enve­lope with ener­gy effi­cient win­dows and doors and roof insu­la­tion, Fox Blocks homes can eas­i­ly meet and exceed ener­gy code require­ments and exceed the min­i­mum require­ments for Ener­gy Star and Ener­Guide. A Fox Blocks struc­ture requires 44% less ener­gy to heat and 32% less ener­gy to cool.

Is the Fox Blocks ICF product ‘LEED’ rated or certified?
Prod­ucts are not rat­ed or cer­ti­fied under the LEED pro­gram. The over­all build­ing is eval­u­at­ed and assigned a LEED rat­ing. In the selec­tion of build­ing mate­ri­als for a LEED design, Fox Blocks have many ben­e­fits that can enable, enhance or direct­ly con­tribute toward LEED points for the project.
What is the difference between Fox Blocks ICFs and the competitors, and why are Fox Blocks ICFs better? Why should I use Fox Blocks ICFs?
Most ICF blocks share com­mon fea­tures and ben­e­fits. Fox Blocks, as a com­pa­ny, pro­vides 30 years’ expe­ri­ence in prod­uct devel­op­ment, doc­u­men­ta­tion, test­ing and train­ing, as well as ver­sa­til­i­ty in the line of prod­ucts to meet all appli­ca­tions. The key dif­fer­ence comes in the exper­tise and sup­port you get from Fox Blocks. Fox Blocks is the leader in insu­lat­ing con­crete form con­struc­tion – proven in over 100,000 com­mer­cial and res­i­den­tial projects across North Amer­i­ca. Exten­sive resources and sup­port sys­tems are avail­able to ensure your project’s suc­cess from start to fin­ish. Please vis­it our web­site www.Fox Blocks​.com to review our project gallery and find more detailed doc­u­men­ta­tion on the prod­ucts and the appli­ca­tions. Fox Blocks also pro­vides a toll free num­ber for Cus­tomer and Tech­ni­cal Sup­port 8773692562.
Does expanded polystyrene (EPS) present a serious fire hazard?
The EPS in an Fox Blocks has a flame retar­dant that allows the forms to be flame resis­tant. The EPS will melt when exposed to sus­tained tem­per­a­tures over 300°F (149°C). The igni­tion point of the melt­ed styrene is 600°F (315°C) (wood is approx­i­mate­ly 500°F (260°C). Fox Blocks have been test­ed to meet the build­ing code require­ments for flame spread and smoke devel­op­ment, plus Fox Blocks may be used as fire resis­tant rat­ed wall assem­blies in schools and hos­pi­tals.
How do frame in openings?
Fox Blocks has devel­oped the Fox Buck specif­i­cal­ly to frame open­ings such as win­dows and doors. The Fox Buck pro­vides insu­la­tion around the open­ing plus sup­port for the attach­ment of the win­dow or door.
Is installing ICFs a DIY project?
Fox Blocks rec­om­mends that all installers using Fox Blocks ICFs com­plete a Fox Blocks train­ing pro­gram to ensure they have a bet­ter under­stand­ing of the basics. How­ev­er, for first time installers, it is pre­ferred that a Fox Blocks trained, expe­ri­enced installer inspect the instal­la­tion pri­or to place­ment of con­crete and assist in the place­ment of the con­crete, as they are famil­iar with work­ing with con­crete and can ensure the build is struc­tural­ly sound and safe and the walls are con­sol­i­dat­ed prop­er­ly, built straight and plumb.
What is a ‘blow-out’?

A blow-out’ is a break in the form, gen­er­al­ly due to the pres­sure from the liq­uid con­crete dur­ing the con­crete place­ment and/​or con­sol­i­da­tion. Fox Blocks ICFs are designed to main­tain a high safe­ty fac­tor of pres­sure from the liq­uid con­crete. Dam­aged forms or fail­ure to sup­port areas where forms have been cut leav­ing a large area of EPS between the web sup­ports may cause a blow-out. Over con­sol­i­da­tion may also cause a blow-out.

Fox Blocks rec­om­mends the Pre-Place­ment Check­list be reviewed for all wall assem­blies pri­or to the place­ment of con­crete, to find poten­tial prob­lem areas and install addi­tion­al strap­ping or sup­port to pre­vent blow-outs. Gen­er­al­ly, for an Fox Blocks form, the size of a blow-out may be lim­it­ed to the EPS between the webs, 6″ or 8″ wide by the height of one form. If a blow-out occurs, the con­crete pour moves to anoth­er area on the wall, the hole is patched by replac­ing the EPS, installing wood sup­port over the area, and then resum­ing the pour.