Do ICFs require a special concrete mix design?
The con­crete is nor­mal strength, min­i­mum 2500 psi (20 MPa) per build­ing codes. The mix design spec­i­fies a small­er aggre­gate and high­er slump than con­crete typ­i­cal­ly used for floors. Most Ready-Mix sup­pli­ers are famil­iar with an ICF con­crete mix design.
Do I need an engineer to design and stamp Fox Blocks building plans?
Fox Blocks are list­ed in the build­ing codes (IRC- Sec­tions R404, R611 or NBCC Part 9) with spe­cif­ic applic­a­bil­i­ty lim­its for res­i­den­tial con­struc­tion. If the project meets the applic­a­bil­i­ty lim­its with­in the build­ing code, a Pro­fes­sion­al Engi­neer may not be required (depen­dent on local build­ing depart­ment require­ments). A build­ing offi­cial has the right to request engi­neer­ing and in some regions all projects require a professional’s stamp. For any projects that exceed the applic­a­bil­i­ty lim­its, a Pro­fes­sion­al Engi­neer is required for the struc­tur­al design. Check with your local build­ing depart­ment.
What size and how much steel reinforcement is required in an ICF?

Fox Blocks walls are designed as rein­forced con­crete walls, with steel rein­force­ment bars spec­i­fied to be installed ver­ti­cal­ly and hor­i­zon­tal­ly, as the walls are built. Typ­i­cal rein­force­ment bar sizes used are #4 or #5 (10 m or 15 m).

Can I install a 16' garage door and / or large openings in a concrete wall?
Yes, if the fol­low­ing cri­te­ria is avail­able for the design of a con­crete lin­tel (beam) over the open­ing – con­crete lin­tel depth min­i­mum 16″ (400 mm) or more with no point loads. Larg­er open­ings would require an engi­neered design.
Can masonry be installed on the exterior walls?
Yes, Fox Blocks has a brick ledge form and the xLer­a­tor ledge rein­force­ment that is designed to sup­port mason­ry. Fox blocks also has a tieKey acces­so­ry which is a specif­i­cal­ly made as a mason­ry tie, to be insert­ed through the form into the con­crete.
Is the Fox Blocks ICF product ‘LEED’ rated or certified?
Prod­ucts are not rat­ed or cer­ti­fied under the LEED pro­gram. The over­all build­ing is eval­u­at­ed and assigned a LEED rat­ing. In the selec­tion of build­ing mate­ri­als for a LEED design, Fox Blocks have many ben­e­fits that can enable, enhance or direct­ly con­tribute toward LEED points for the project.
When is a Taper Top form required?
Taper Top forms are specif­i­cal­ly designed to pro­vide a larg­er bear­ing sur­face along the top of the wall. Typ­i­cal­ly, the increased bear­ing sur­face may be used to sup­port mason­ry, floor or roof loads. Taper top forms are used in the tran­si­tion from ICF to wood frame con­struc­tion and the taper top form would be the top form on the wall.
Is there a problem when placing concrete, dropping concrete from the top of the wall which may be over 8' (2.4 m)?
No. Spec­i­fi­ca­tions in the Amer­i­ca Con­crete Insti­tute (ACI) do not lim­it the max­i­mum dis­tance con­crete can free fall. Engi­neer­ing stud­ies and reports have shown that free fall from up to 35′ doesn’t reduce con­crete qual­i­ty and there is no evi­dence of seg­re­ga­tion or weak­ened con­crete strength. ICF con­crete design calls for a high slump mix which assists in reduc­ing seg­re­ga­tion.
How do I determine which size ICF to use?

ICFs pro­vide a rein­forced con­crete wall which is designed to spe­cif­ic engi­neer­ing prin­ci­ples. Typ­i­cal res­i­den­tial con­struc­tion, per the applic­a­bil­i­ty lim­its in the build­ing code, allows walls 10′ (3 m) high or less between lat­er­al sup­ports (floor and roof con­nec­tions). Below grade walls must have a min­i­mum 6″ (150 mm) con­crete core. In some regions, an 8″ (200 mm) con­crete core is the min­i­mum allowed thick­ness for below grade walls.

The 4″ (100 mm) form can­not be used below grade as a foun­da­tion wall. The 4″ (100 mm) form may be used for above grade walls up to a max­i­mum of 10′ (3.0 m).

The 6″ (150 mm) form, above grade, is lim­it­ed to approx­i­mate­ly 14′ (4.2 m) in height. Walls high­er than 14′ (4.2 m) must use an 8″ (200 mm) or larg­er form.

Typ­i­cal res­i­den­tial con­struc­tion will use 6″ or 8″ con­crete core size blocks. Project spe­cif­ic engi­neer­ing may allow for some core thick­ness to span ver­ti­cal­ly high­er than these pro­posed guide­lines.

What is a ‘blow-out’?

A blow-out’ is a break in the form, gen­er­al­ly due to the pres­sure from the liq­uid con­crete dur­ing the con­crete place­ment and/​or con­sol­i­da­tion. Fox Blocks ICFs are designed to main­tain a high safe­ty fac­tor of pres­sure from the liq­uid con­crete. Dam­aged forms or fail­ure to sup­port areas where forms have been cut leav­ing a large area of EPS between the web sup­ports may cause a blow-out. Over con­sol­i­da­tion may also cause a blow-out.

Fox Blocks rec­om­mends the Pre-Place­ment Check­list be reviewed for all wall assem­blies pri­or to the place­ment of con­crete, to find poten­tial prob­lem areas and install addi­tion­al strap­ping or sup­port to pre­vent blow-outs. Gen­er­al­ly, for an Fox Blocks form, the size of a blow-out may be lim­it­ed to the EPS between the webs, 6″ or 8″ wide by the height of one form. If a blow-out occurs, the con­crete pour moves to anoth­er area on the wall, the hole is patched by replac­ing the EPS, installing wood sup­port over the area, and then resum­ing the pour.