When can I backfill the foundation wall?
The con­crete must cure for a min­i­mum of 7 days and the foun­da­tion wall must be lat­er­al­ly sup­port­ed, mean­ing the floor sys­tem is installed sup­port­ing the top of the wall. All below grade water­proof­ing / damp­proof­ing must be installed.
How do I apply traditional stucco to an ICF?

Tra­di­tion­al stuc­co has a thick cemen­ti­tious base, typ­i­cal­ly installed over a met­al lath. The met­al lath is fas­tened direct­ly to the Fox Blocks webs with screw or sta­ples.

Can I install a 16' garage door and / or large openings in a concrete wall?
Yes, if the fol­low­ing cri­te­ria is avail­able for the design of a con­crete lin­tel (beam) over the open­ing – con­crete lin­tel depth min­i­mum 16″ (400 mm) or more with no point loads. Larg­er open­ings would require an engi­neered design.
Can masonry be installed on the exterior walls?
Yes, Fox Blocks has a brick ledge form and the xLer­a­tor ledge rein­force­ment that is designed to sup­port mason­ry. Fox blocks also has a tieKey acces­so­ry which is a specif­i­cal­ly made as a mason­ry tie, to be insert­ed through the form into the con­crete.
What fasteners are recommended for ICFs?

Fox Blocks has con­duct­ed numer­ous fas­ten­er tests for pull-out strength and shear capac­i­ty for var­i­ous fas­ten­ers – screws, ring shank nails and sta­ples into the plas­tic webs. The rec­om­men­da­tion for inte­ri­or and exte­ri­or appli­ca­tions of fin­ish mate­ri­als is for the use of screws which pro­vide the best hold­ing capac­i­ty into the plas­tic webs or fas­ten­ing strips in the forms which are iden­ti­fied on each block.

The EPS insu­la­tion does not pro­vide any hold­ing capac­i­ty for fas­ten­ers.

Does EPS absorb water?
No, EPS is a closed cell foam and does not act like a sponge or absorb water.
What is the R-Value?

The clear R‑Value of an Fox Blocks is R22, how­ev­er cur­rent Ener­gy codes rec­og­nize the lack of ther­mal bridg­ing in an ICF and the con­tri­bu­tion of the mass con­crete on the influ­ence of the ther­mal per­for­mance. Whole wall cal­cu­la­tions indi­cate a Fox blocks wall assem­bly pro­vides an R24 rat­ing.

The con­tin­u­ous dou­ble lay­er (inside and out­side) of insu­la­tion, the elim­i­na­tion of ther­mal bridg­ing and min­i­mal air infil­tra­tion through the mass con­crete wall assem­bly, allows Fox Blocks walls to per­for­mance in the high per­for­mance wall assem­bly cat­e­go­ry. Com­plet­ing the enve­lope with ener­gy effi­cient win­dows and doors and roof insu­la­tion, Fox Blocks homes can eas­i­ly meet and exceed ener­gy code require­ments and exceed the min­i­mum require­ments for Ener­gy Star and Ener­Guide. A Fox Blocks struc­ture requires 44% less ener­gy to heat and 32% less ener­gy to cool.

Is a vapor barrier required on the inside face of an ICF wall?
No. The char­ac­ter­is­tics of an ICF wall with the mass con­crete and the EPS insu­la­tion pro­vide the required vapor per­me­ance to meet build­ing code require­ments as a vapor bar­ri­er.
Do I have to finish my basement walls with drywall?
All build­ing codes in the USA and Cana­da spec­i­fy that plas­tic insu­la­tion (EPS) must be cov­ered by a ther­mal bar­ri­er equiv­a­lent to 15 min­utes of fire pro­tec­tion in hab­it­able spaces. If the base­ment is clas­si­fied as hab­it­able space, then gyp­sum board must be applied but does have to taped and filled. Check with your local build­ing offi­cial.
What is the typical Interior finish on an ICF?

All build­ing codes in the USA and Cana­da spec­i­fy that plas­tic insu­la­tion (EPS) must be cov­ered by a ther­mal bar­ri­er equiv­a­lent to 15 min­utes of fire pro­tec­tion in hab­it­able spaces. This is achieved with ½” gyp­sum board or an equiv­a­lent mate­r­i­al. Fox Blocks has spe­cif­ic fire test­ing that proves reg­u­lar ½” gyp­sum board with reg­u­lar dry­wall screws fas­tened into the plas­tic webs remains on the wall for the required 15-minute time peri­od.