Fox Blocks has conducted numerous fastener tests for pull-out strength and shear capacity for various fasteners – screws, ring shank nails and staples into the plastic webs. The recommendation for interior and exterior applications of finish materials is for the use of screws which provide the best holding capacity into the plastic webs or fastening strips in the forms which are identified on each block.
The EPS insulation does not provide any holding capacity for fasteners.





All ICF walls below grade, that have habitable space on one side (basement), must have a waterproofing / dampproofing membrane installed. For walls that do not have habitable space on one side (crawl space, frost walls, etc.) the EPS can be left exposed to the earth. The EPS will not deteriorate when exposed to the earth.